View stock (México)
SICOM3028GPT
28 port layer 2/3 managed rack mountable modular switches

SICOM3028GPT is a intelligent modular platform which is an All-in-One solution integrating IEEE1588v2, Sync-E, full gigabit, and both layer 2 & Layer 3 availability specifically designed to operate reliably in electrically harsh and climatically demanding utility substation and industrial environments. SICOM3028GPT supports up to 28 gigabit fiber/copper ports, meets the IEC61850 and IEEE1613 standards. SICOM3028GPT is a 19-inch 1U rack mountable device and supports one 1U slot and six 0.5U slots which offers the maximum flexibility for easy expansion.SICOM3028GPT supports IEEE1588v2 and synchronous Ethernet protocol with hardware time stamping and supports the BC, P2P TC, and E2E TC clock modes, it reaches a timing precision of 100 ns. It supports Power Profile and Telecom Profile, and supports many modules for time synchronous like HSR/PRP, TimeServer, GPS, IRIG-B and TMS-trigger etc.
SICOM3028GPT supports many Layer 2 software features such as port, VLAN, multicast, QoS, fast redundant ring and Layer 3 functions such as VRRP, RIP, OSFP, IGMP and PIM. It supports Console, Telnet, Web management and network management software based on SNMP. By expanding the serial server module, the product can provide up to 24 RS232/422/485 serial ports. At present, the product is widely used at the intelligent substation and many other industrial communication systems.inteligentes y otros sistemas de comunicación industrial.
Main Features
Flexible modular design for easy expansion, supports max 28 gigabit fiber/copper ports.
Supports DT-Ring ,DRP, MSTP and VRRP for network redundancy.
Supports Layer 3 routing protocols such as RIP and OSPF.
Supports IEEE1588v2 and the synchronization precision reaches ±100 ns, with SW based PTP 1588 and optional HW based PTP 1588.
Supports ITU-T.G.8261/G.8262 synchronous Ethernet and the synchronization precision reaches ±50 ns.
Supports HSR/PRP module, TimeServer module, GPS module, IRIG-B module, TMS-trigger module, Serial server module, LED module.
Supports Hot-Swappable Power Supplies.
Supports IEC61850 MMS management.
Supports cable test.
Complies with IEC61850-3 and IEEE1613.
KEMA, CE, FCC, EN50155/EN50121, UL61010, NEMA-TS2.
Ordering Information
Product selection table
Sub-model | Ethernet Ports | L2 function | L3 function | Time synchronization |
SICOM3028GPT-L2GT | Up to 28 Gigabit ports | ● |
| ● |
SICOM3028GPT-L2G | Up to 28 Gigabit ports | ● |
|
|
SICOM3028GPT-L2FT | Up to 4 Gigabit ports and 24 Fast Ethernet ports | ● |
| ● |
SICOM3028GPT-L2F | Up to 4 Gigabit ports and 24 Fast Ethernet ports | ● |
|
|
SICOM3028GPT-L3GT | Up to 28 Gigabit ports | ● | ● | ● |
SICOM3028GPT-L3G | Up to 28 Gigabit ports | ● | ● |
|
SICOM3028GPT-L3FT | Up to 4 Gigabit ports and 24 Fast Ethernet ports | ● | ● | ● |
SICOM3028GPT-L3F | Up to 4 Gigabit ports and 24 Fast Ethernet ports | ● | ● |
|
Ordering Information
Recommended model
Product Model | SICOM3028GPT-SM-PS1-PS2 |
Code definition | Code selection |
SM: Sub-model | L2GT-MB: SICOM3028GPT 28G ports L2 Chassis with time synchronization L2G-MB: SICOM3028GPT 28G ports L2 Chassis L2FT-MB: SICOM3028GPT 24+4G ports L2 Chassis with time synchronization L2F-MB: SICOM3028GPT 24+4G ports L2 Chassis L3GT-MB: SICOM3028GPT 28G ports L3 Chassis with time synchronization L3G-MB: SICOM3028GPT 28G ports L3 Chassis L3FT-MB: SICOM3028GPT 24+4G ports L3 Chassis with time synchronization L3F-MB: SICOM3028GPT 24+4G ports L3 Chassis |
PS1: power input 1 | HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC) L1=48VDC(36-72VDC) L3=24VDC(18-36VDC) |
PS2: power input 2 | HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC) L1=48VDC(36-72VDC) L3=24VDC(18-36VDC) NA: no redundant power supply |
|
|
Hot-Swappable Chassis | SICOM3028GPT-SM |
SM: Sub-model | L2GT-MB: SICOM3028GPT 28G ports L2 Chassis with time synchronization L2G-MB: SICOM3028GPT 28G ports L2 Chassis L2FT-MB: SICOM3028GPT 24+4G ports L2 Chassis with time synchronization L2F-MB: SICOM3028GPT 24+4G ports L2 Chassis L3GT-MB: SICOM3028GPT 28G ports L3 Chassis with time synchronization L3G-MB: SICOM3028GPT 28G ports L3 Chassis L3FT-MB: SICOM3028GPT 24+4G ports L3 Chassis with time synchronization L3F-MB: SICOM3028GPT 24+4G ports L3 Chassis |
Hot-Swappable Power Module | SM6.6-Power-PS |
PS: power input | HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC), 1U L1=48VDC(36-72VDC), 1U L3=24VDC(18-36VDC), 1U |
|
|
Slot 1: | SM6.6-Ports-1U |
Ports: | 4GX=4x1000Base-X, 10/100/1000Base-T(X) SFP port,1U 4GX-DDM=4x1000Base-X, 10/100/1000Base-T(X) SFP port, DDM, 1U 4GE=4x10/100/1000Base-T(X) RJ45 port, 1U 2GX2GE=2x1000Base-X, 10/100/1000Base-T(X) SFP port; 2x10/100/1000Base-T(X) RJ45 port, 1U |
Slot2-Slot7: | SM6.6-Ports-Connector-0.5U |
Ports: | 4GX=4x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port, 0.5U 4GX-DDM=4x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port, DDM, 0.5U 4SFP-DDM=4x100Base-FX SFP port, DDM, 0.5U 4GE=4x10/100/1000Base-T(X) RJ45 port, 0.5U 2GX2GE=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x10/100/1000Base-T(X) RJ45 port, 0.5U 2GX2S=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x100Base-FX, single-mode fiber port, 0.5U 2GX2M=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x100Base-FX, multi-mode fiber port, 0.5U 4S=4x100Base-FX, single-mode fiber port, 0.5U 4M=4x100Base-FX, multi-mode fiber port, 0.5U 2S2T=2x100Base-FX, single-mode fiber port; 2x10/100Base-T(X) RJ45 port, 0.5U 2M2T=2x100Base-FX, multi-mode fiber port; 2x10/100Base-T(X) RJ45 port, 0.5U 4T=4x10/100Base-T(X) RJ45 port, 0.5U |
Connector: 100M fiber port specifications | SC05=SC connector, multi-mode, 1310nm, 5km ST05=ST connector, multi-mode, 1310nm, 5km FC05=FC connector, multi-mode, 1310nm, 5km SC40=SC connector, single-mode, 1310nm, 40km ST40=ST connector, single-mode, 1310nm, 40km FC40=FC connector, single-mode, 1310nm, 40km SC60=SC connector, single-mode, 1310nm, 60km SC80=SC connector, single-mode, 1550nm, 80km |
Slot2-Slot7: | Module |
| SM6.6-HSR/PRP-GE-0.5U = Redbox module, 2x100/1000Base-T RJ45 port SM6.6-HSR/PRP-GX-0.5U = Redbox module, 2x1000Base-X, 100Base-FX SFP port SM6.6-PTP-BO-0.5U = PTP-to-IRIG-B convertor module, 2 IRIG-B(AC) outputs, 2 IRIG-B(DC) outputs, 1 PPS outputSM6.6-GPS-OI-0.5U = GPS clock synchronization module, 1 GPS antenna input, 1 PPS outputSM6.6-4D-232/422/485-0.5U = serial port server module, 4 RS232/422/485 serial portsSM6.6-4D-A-4RS232/422/485-0.5U = enhanced serial port server module, 4 RS232/422/485 serial ports, supports flow control and optical/electrical isolationSM6.6-TMS-Trigger-1U = Time Management System trigger module, 1 IRIG-B output, 1 IRIG-B input, 2 channels for signal input, 2 channels for signal output, 1 Console portSM6.6-TimeServer-ST850-1U = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web.SM6.6-TimeServer-ST850-1U-S1 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,SNMPSM6.6-TimeServer-ST850-1U-S2 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,DNP3.0,IEC60870-5-104SM6.6-TimeServer-ST850-1U-S3 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,IEC61850 MMS,IEC60870-5-104SM6.6-TimeServer-ST850-1U-S4 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,TMS,IEC61850 MMS,IEC60870-5-104SM6.6-TimeServer-ST1310-1U = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; WebSM6.6-TimeServer-ST1310-1U-S1 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web ,SNMPSM6.6-TimeServer-ST1310-1U-S2 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web,DNP3.0,IEC60870-5-104SM6.6-TimeServer-ST1310-1U-S3 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web,IEC61850 MMS,IEC60870-5-104SM6.6-TimeServer-ST1310-1U-S4 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web,TMS,IEC61850 MMS,IEC60870-5-104 |
Slot7: | Module |
| SM6.6-LED-0.5U = LED module, Alarm LED, Running LED, Power LED, Port LED |
Module adaptive table
| SICOM3028GPT | |||||||
| L2GT | L2G | L2FT | L2F | L3GT | L3G | L3FT | L3F |
SM6.6-LED-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-HSR/PRP-GE-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-HSR/PRP-GX-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-PTP-BO-0.5U | √ |
| √ |
| √ |
| √ |
|
SM6.6-GPS-OI-0.5U | √ |
| √ |
| √ |
| √ |
|
SM6.6-TMS-Trigger-1U | √ |
| √ |
| √ |
| √ |
|
SM6.6-TimeServer-ST850-1U | √ |
| √ |
| √ |
| √ |
|
SM6.6-TimeServer-ST850-1U-S1 | √ |
| √ |
| √ |
| √ |
|
SM6.6-TimeServer-ST850-1U-S2 | √ |
| √ |
| √ |
| √ |
|
SM6.6-TimeServer-ST850-1U-S3 | √ |
| √ |
| √ |
| √ |
|
SM6.6-TimeServer-ST850-1U-S4 | √ |
| √ |
| √ |
| √ |
|
SM6.6-TimeServer-ST1310-1U | √ |
| √ |
| √ |
| √ |
|
SM6.6-TimeServer-ST1310-1U-S1 | √ |
| √ |
| √ |
| √ |
|
SM6.6-TimeServer-ST1310-1U-S2 | √ |
| √ |
| √ |
| √ |
|
SM6.6-TimeServer-ST1310-1U-S3 | √ |
| √ |
| √ |
| √ |
|
SM6.6-TimeServer-ST1310-1U-S4 | √ |
| √ |
| √ |
| √ |
|
SM6.6-4D-232/422/485-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4D-A-4RS232/422/485-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4GX-1U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4GX-DDM-1U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4GE-1U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2GX2GE-1U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4GX-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-4GX-DDM-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-4SFP-DDM-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4GE-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-2GX2GE-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-2GX2M-ST05-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-2GX2M-SC05-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-2GX2M-FC05-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-2GX2S-ST40-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-2GX2S-SC40-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-2GX2S-FC40-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-2GX2S-SC60-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-2GX2S-SC80-0.5U | √ | √ |
|
| √ | √ |
|
|
SM6.6-4M-ST05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4M-SC05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4M-FC05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4S-ST40-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4S-SC40-0.5U | √ | √ | √ | √ | √ | √ | √ | |
SM6.6-4S-FC40-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4S-SC60-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-4S-SC80-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2M2T-ST05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2M2T-SC05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2M2T-FC05-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2S2T-ST40-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2S2T-SC40-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2S2T-FC40-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2S2T-SC60-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
SM6.6-2S2T-SC80-0.5U | √ | √ | √ | √ | √ | √ | v | √ |
SM6.6-4T-0.5U | √ | √ | √ | √ | √ | √ | √ | √ |
Accessories
Accessory Model | Description |
Gigabit SFP module | See the selection table of industrial gigabit SFP module |
100M SFP module | See the selection table of industrial 100M SFP module |
DT-FCZ-RJ45-01 | Single-port RJ45 dust plug |
DT-XL- Mini USB-USB-2m | 2m USB console cable |
DT-ZJQ-BNC-TNC-01 | BNC(female) to TNC(female) connector |
DT-XL-LMR400-TNC-BNC-20m | 20m coaxial cable with BNC(male) to TNC(male) adaptor |
DT-XL-LMR400-TNC-BNC-2m | 2m coaxial cable with BNC(male) to TNC(male) adaptor |
DT-GPS-ANT-01 | GPS antenna, 5 V DC power supply, 1 TNC connector(female) |
DT-SP-01 | GPS surge protection, TNC connector(male) – TNC connector(female) |
Download