SICOM3028GPT

28 port layer 2/3 managed rack mountable modular switches

SICOM3028GPT
KylandTR6.png
KylandTR6.png

SICOM3028GPT is a intelligent modular platform which is an All-in-One solution integrating IEEE1588v2, Sync-E, full gigabit, and both layer 2 & Layer 3 availability specifically designed to operate reliably in electrically harsh and climatically demanding utility substation and industrial environments. SICOM3028GPT supports up to 28 gigabit fiber/copper ports, meets the IEC61850 and IEEE1613 standards. SICOM3028GPT is a 19-inch 1U rack mountable device and supports one 1U slot and six 0.5U slots which offers the maximum flexibility for easy expansion.SICOM3028GPT supports IEEE1588v2 and synchronous Ethernet protocol with hardware time stamping and supports the BC, P2P TC, and E2E TC clock modes, it reaches a timing precision of 100 ns. It supports Power Profile and Telecom Profile, and supports many modules for time synchronous like HSR/PRP, TimeServer, GPS, IRIG-B and TMS-trigger etc.

SICOM3028GPT supports many Layer 2 software features such as port, VLAN, multicast, QoS, fast redundant ring and Layer 3 functions such as VRRP, RIP, OSFP, IGMP and PIM. It supports Console, Telnet, Web management and network management software based on SNMP. By expanding the serial server module, the product can provide up to 24 RS232/422/485 serial ports. At present, the product is widely used at the intelligent substation and many other industrial communication systems.inteligentes y otros sistemas de comunicación industrial.

Main Features
  • Flexible modular design for easy expansion, supports max 28 gigabit fiber/copper ports.

  • Supports DT-Ring ,DRP, MSTP and VRRP for network redundancy.

  • Supports Layer 3 routing protocols such as RIP and OSPF.

  • Supports IEEE1588v2 and the synchronization precision reaches ±100 ns, with SW based PTP 1588 and optional HW based PTP 1588.

  • Supports ITU-T.G.8261/G.8262 synchronous Ethernet and the synchronization precision reaches ±50 ns.

  • Supports HSR/PRP module, TimeServer module, GPS module, IRIG-B module, TMS-trigger module, Serial server module, LED module.

  • Supports Hot-Swappable Power Supplies.

  • Supports IEC61850 MMS management.

  • Supports cable test.

  • Complies with IEC61850-3 and IEEE1613.

  • KEMA, CE, FCC, EN50155/EN50121, UL61010, NEMA-TS2.

Ordering Information

Product selection table

Sub-model

Ethernet Ports

L2 function

L3 function

Time synchronization

SICOM3028GPT-L2GT

Up to 28 Gigabit ports

 

SICOM3028GPT-L2G

Up to 28 Gigabit ports

 

 

SICOM3028GPT-L2FT

Up to 4 Gigabit ports and 24 Fast Ethernet ports

 

SICOM3028GPT-L2F

Up to 4 Gigabit ports and 24 Fast Ethernet ports

 

 

SICOM3028GPT-L3GT

Up to 28 Gigabit ports

SICOM3028GPT-L3G

Up to 28 Gigabit ports

 

SICOM3028GPT-L3FT

Up to 4 Gigabit ports and 24 Fast Ethernet ports

SICOM3028GPT-L3F

Up to 4 Gigabit ports and 24 Fast Ethernet ports

 

 

Ordering Information

Recommended model

Product Model

SICOM3028GPT-SM-PS1-PS2

Code definition

Code selection

SM: Sub-model

L2GT-MB: SICOM3028GPT 28G ports L2 Chassis with time synchronization


L2G-MB: SICOM3028GPT 28G ports L2 Chassis


L2FT-MB: SICOM3028GPT 24+4G ports L2 Chassis with time synchronization


L2F-MB: SICOM3028GPT 24+4G ports L2 Chassis


L3GT-MB: SICOM3028GPT 28G ports L3 Chassis with time synchronization


L3G-MB: SICOM3028GPT 28G ports L3 Chassis


L3FT-MB: SICOM3028GPT 24+4G ports L3 Chassis with time synchronization


L3F-MB: SICOM3028GPT 24+4G ports L3 Chassis

PS1: power input 1

HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC)


L1=48VDC(36-72VDC)


L3=24VDC(18-36VDC)

PS2: power input 2

HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC)


L1=48VDC(36-72VDC)


L3=24VDC(18-36VDC)


NA: no redundant power supply

 

 

Hot-Swappable Chassis

SICOM3028GPT-SM

SM: Sub-model

L2GT-MB: SICOM3028GPT 28G ports L2 Chassis with time synchronization


L2G-MB: SICOM3028GPT 28G ports L2 Chassis


L2FT-MB: SICOM3028GPT 24+4G ports L2 Chassis with time synchronization


L2F-MB: SICOM3028GPT 24+4G ports L2 Chassis


L3GT-MB: SICOM3028GPT 28G ports L3 Chassis with time synchronization


L3G-MB: SICOM3028GPT 28G ports L3 Chassis


L3FT-MB: SICOM3028GPT 24+4G ports L3 Chassis with time synchronization


L3F-MB: SICOM3028GPT 24+4G ports L3 Chassis

Hot-Swappable Power Module

SM6.6-Power-PS

PS:  power input

HV=100-240VAC,50/60Hz;110-220VDC(85-264VAC/77-300VDC), 1U

L1=48VDC(36-72VDC), 1U


L3=24VDC(18-36VDC), 1U

 

 

Slot 1:

SM6.6-Ports-1U

Ports:

4GX=4x1000Base-X, 10/100/1000Base-T(X) SFP port,1U


4GX-DDM=4x1000Base-X, 10/100/1000Base-T(X) SFP port, DDM, 1U


4GE=4x10/100/1000Base-T(X) RJ45 port, 1U


2GX2GE=2x1000Base-X, 10/100/1000Base-T(X) SFP port; 2x10/100/1000Base-T(X) RJ45 port, 1U

Slot2-Slot7:

SM6.6-Ports-Connector-0.5U

Ports:

4GX=4x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port, 0.5U


4GX-DDM=4x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port, DDM, 0.5U


4SFP-DDM=4x100Base-FX SFP port, DDM, 0.5U


4GE=4x10/100/1000Base-T(X) RJ45 port, 0.5U


2GX2GE=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x10/100/1000Base-T(X) RJ45 port, 0.5U


2GX2S=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x100Base-FX, single-mode fiber port, 0.5U


2GX2M=2x1000Base-X, 100Base-FX, 10/100/1000Base-T(X) SFP port; 2x100Base-FX, multi-mode fiber port, 0.5U


4S=4x100Base-FX, single-mode fiber port, 0.5U


4M=4x100Base-FX, multi-mode fiber port, 0.5U


2S2T=2x100Base-FX, single-mode fiber port; 2x10/100Base-T(X) RJ45 port, 0.5U


2M2T=2x100Base-FX, multi-mode fiber port; 2x10/100Base-T(X) RJ45 port, 0.5U


4T=4x10/100Base-T(X) RJ45 port, 0.5U

Connector: 100M fiber port specifications

SC05=SC connector, multi-mode, 1310nm, 5km


ST05=ST connector, multi-mode, 1310nm, 5km


FC05=FC connector, multi-mode, 1310nm, 5km


SC40=SC connector, single-mode, 1310nm, 40km


ST40=ST connector, single-mode, 1310nm, 40km


FC40=FC connector, single-mode, 1310nm, 40km


SC60=SC connector, single-mode, 1310nm, 60km


SC80=SC connector, single-mode, 1550nm, 80km

Slot2-Slot7:

Module

 

SM6.6-HSR/PRP-GE-0.5U  = Redbox module, 2x100/1000Base-T RJ45 port SM6.6-HSR/PRP-GX-0.5U  = Redbox module, 2x1000Base-X, 100Base-FX SFP port SM6.6-PTP-BO-0.5U = PTP-to-IRIG-B convertor module, 2 IRIG-B(AC) outputs, 2 IRIG-B(DC) outputs, 1 PPS outputSM6.6-GPS-OI-0.5U = GPS clock synchronization module, 1 GPS antenna input, 1 PPS outputSM6.6-4D-232/422/485-0.5U = serial port server module, 4 RS232/422/485 serial portsSM6.6-4D-A-4RS232/422/485-0.5U = enhanced serial port server module, 4 RS232/422/485 serial ports, supports flow control and optical/electrical isolationSM6.6-TMS-Trigger-1U = Time Management System trigger module, 1 IRIG-B output, 1 IRIG-B input, 2 channels for signal input, 2 channels for signal output, 1 Console portSM6.6-TimeServer-ST850-1U = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web.SM6.6-TimeServer-ST850-1U-S1 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,SNMPSM6.6-TimeServer-ST850-1U-S2 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,DNP3.0,IEC60870-5-104SM6.6-TimeServer-ST850-1U-S3 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,IEC61850 MMS,IEC60870-5-104SM6.6-TimeServer-ST850-1U-S4 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,850nm; 1 Gigabit combo port; 1 console port; Web,TMS,IEC61850 MMS,IEC60870-5-104SM6.6-TimeServer-ST1310-1U = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; WebSM6.6-TimeServer-ST1310-1U-S1 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web ,SNMPSM6.6-TimeServer-ST1310-1U-S2 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web,DNP3.0,IEC60870-5-104SM6.6-TimeServer-ST1310-1U-S3 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web,IEC61850 MMS,IEC60870-5-104SM6.6-TimeServer-ST1310-1U-S4 = TimeServer module, 1 satellite antenna input; 1 TTL output; 1 RS485 output; 1 optical input and 1 optical output,1310nm; 1 Gigabit combo port; 1 console port; Web,TMS,IEC61850 MMS,IEC60870-5-104

Slot7:

Module

 

SM6.6-LED-0.5U = LED module, Alarm LED, Running LED, Power LED, Port LED

 

Module adaptive table








 

SICOM3028GPT

 

L2GT

L2G

L2FT

L2F

L3GT

L3G

L3FT

L3F

SM6.6-LED-0.5U

SM6.6-HSR/PRP-GE-0.5U

SM6.6-HSR/PRP-GX-0.5U

SM6.6-PTP-BO-0.5U

 

 

 

 

SM6.6-GPS-OI-0.5U

 

 

 

 

SM6.6-TMS-Trigger-1U

 

 

 

 

SM6.6-TimeServer-ST850-1U

 

 

 

 

SM6.6-TimeServer-ST850-1U-S1

 

 

 

 

SM6.6-TimeServer-ST850-1U-S2

 

 

 

 

SM6.6-TimeServer-ST850-1U-S3

 

 

 

 

SM6.6-TimeServer-ST850-1U-S4

 

 

 

 

SM6.6-TimeServer-ST1310-1U

 

 

 

 

SM6.6-TimeServer-ST1310-1U-S1

 

 

 

 

SM6.6-TimeServer-ST1310-1U-S2

 

 

 

 

SM6.6-TimeServer-ST1310-1U-S3

 

 

 

 

SM6.6-TimeServer-ST1310-1U-S4

 

 

 

 

SM6.6-4D-232/422/485-0.5U

SM6.6-4D-A-4RS232/422/485-0.5U

SM6.6-4GX-1U

SM6.6-4GX-DDM-1U

SM6.6-4GE-1U

SM6.6-2GX2GE-1U

SM6.6-4GX-0.5U

 

 

 

 

SM6.6-4GX-DDM-0.5U

 

 

 

 

SM6.6-4SFP-DDM-0.5U

SM6.6-4GE-0.5U

 

 

 

 

SM6.6-2GX2GE-0.5U

 

 

 

 

SM6.6-2GX2M-ST05-0.5U

 

 

 

 

SM6.6-2GX2M-SC05-0.5U

 

 

 

 

SM6.6-2GX2M-FC05-0.5U

 

 

 

 

SM6.6-2GX2S-ST40-0.5U

 

 

 

 

SM6.6-2GX2S-SC40-0.5U

 

 

 

 

SM6.6-2GX2S-FC40-0.5U

 

 

 

 

SM6.6-2GX2S-SC60-0.5U

 

 

 

 

SM6.6-2GX2S-SC80-0.5U

 

 

 

 

SM6.6-4M-ST05-0.5U

SM6.6-4M-SC05-0.5U

SM6.6-4M-FC05-0.5U

SM6.6-4S-ST40-0.5U

SM6.6-4S-SC40-0.5U

SM6.6-4S-FC40-0.5U

SM6.6-4S-SC60-0.5U

SM6.6-4S-SC80-0.5U

SM6.6-2M2T-ST05-0.5U

SM6.6-2M2T-SC05-0.5U

SM6.6-2M2T-FC05-0.5U

SM6.6-2S2T-ST40-0.5U

SM6.6-2S2T-SC40-0.5U

SM6.6-2S2T-FC40-0.5U

SM6.6-2S2T-SC60-0.5U

SM6.6-2S2T-SC80-0.5U

v

SM6.6-4T-0.5U

 

Accessories

Accessory Model

Description

Gigabit SFP module

See the selection table of industrial gigabit SFP module

100M SFP module

See the selection table of industrial 100M SFP module

DT-FCZ-RJ45-01

Single-port RJ45 dust plug

DT-XL- Mini USB-USB-2m

2m USB console cable

DT-ZJQ-BNC-TNC-01

BNC(female) to TNC(female) connector

DT-XL-LMR400-TNC-BNC-20m

20m coaxial cable with BNC(male) to TNC(male) adaptor

DT-XL-LMR400-TNC-BNC-2m

2m coaxial cable with BNC(male) to TNC(male) adaptor

DT-GPS-ANT-01

GPS antenna, 5 V DC power supply, 1 TNC connector(female)

DT-SP-01

GPS surge protection, TNC connector(male) – TNC connector(female)


Download


©2024 by Myrtos. All rights reserved.