Medidor ION8650C
M8650B0C0H6E1A1A


The PowerLogic ION8650 series meters are ideal for independent power producers, power quality measurement, and energy metering. These meters offer a wide range of features and overall performance. The meter can be the solution for the transmission or distribution network.
ION's modular and flexible architecture enables a simple, key-component approach to customizing each meter to any application. It provides user access to energy analysis, bill verification, cost allocation, and more, along with a range of power quality reports. With 32 MB of memory, it supports data logging, alarms, RMS logging, historical logs, event logs, revenue logs, GPS synchronization, and usage time tracking.
The ability to perform timestamp events at +/-1 ms using time synchronization methods including SNTP, IRIG-B, GPS ASCII (RS485), and network time adjustment. It provides 1024 samples per cycle with voltage inputs of 57-277 V AC L-N / 100-480 V AC L-L; and current inputs of 1 A, 2 A, and 5 A. It offers a wide control power range of 57 to 277 V AC or an external power supply: 65-120 V AC or 80-160 V DC flexible cable.
The integrated input/output configuration includes 3 digital inputs, 2 pulse outputs, and 4 relay outputs, plus up to 3 dry contact detection inputs. Multiple communication ports include RS232/RS485, RS485, infrared (ANSI Type II), and 10/100 BASE-T Ethernet. The mechanical dimensions are 178 mm high, 178 mm wide, and 237 mm deep, with a product weight of 7 kg. It features a socket form factor and is compatible with 9S/29S/36S 3-element, 4-wire or 2.5-element, 4-wire base cabling. It includes an integrated display. Operating environment ranges from -40 to +85°C; nominal humidity from 5% to 95%; and altitude up to 3000 m.
Main Features
Main | |
Range | PowerLogic |
Product name | PowerLogic ION8650 |
Device short name | ION8650C |
Product or Component Type | Revenue and power quality meter |
Complementary | |
Power quality analysis | harmonic distortion programmablity (logic and math functions) voltage sag and swell detection up to the 31st harmonic |
Device Application | Equipment monitoring and control Co-generation and IPP monitoring Instrument transformer correction Energy pulsing and totalisation Load curtailment Tariff metering Demand and power factor control |
Type of measurement | Power factor total Power factor per phase Apparent power total Apparent power per phase Active power total Active power per phase Reactive power total Reactive power per phase Current Voltage Frequency |
supply voltage | 120...277 V AC 47...63 Hz 65...120 V AC 47...63 Hz 80...160 V DC |
Network Frequency | 60 Hz |
Outlet standard | American |
Line Rated Current | 5 A 1 A 2 A |
Poles description | 3P + N 3P 1P + N |
Power consumption in VA | 24 VA |
Maximum power consumption in VA | 33 VA |
Display Type | FSTN transflective LCD |
Form designation | 9S 3-element 4 36S 2½-element 4 29S 2½-element 4 |
Sampling rate | 1024 samples/cycle |
Measurement current | 0.001…24 A |
input type | Current 0.01...20 A (impedance 0.05 Ohm) |
Measurement voltage | 57…277 V AC phase to neutral 100…480 V AC phase to phase |
Number of inputs | 0 |
Measurement accuracy | Current 0.1 % Voltage 0.1 % Power 0.1 % Power factor 0.1 % Frequency 0.001 Hz Energy 0.1 % |
Accuracy class | Class 0.2S energy IEC 62053-22 Class 0.2S energy IEC 62053-23 Class 0.2 energy ANSI C12.20 |
Number of Outputs | 2 pulse |
Communication port protocol | TCP/IP 10/100 Mbit/s DNP3 300...115200 bauds ION 300...115200 bauds DLMS 300...115200 bauds Modbus 57600 bauds Ansi C12.18 <= 19200 bauds DNP3 10/100 Mbit/s ION 10/100 Mbit/s IEC 61850 ed. 2 10/100 Mbit/s TCP/IP 300...57600 bauds EtherGate ModemGate Modbus RTU, slave 300...115200 bauds Modbus TCP, slave 10/100 Mbit/s |
Communication port support | RJ11 modem RJ45 ETHERNET SUB-D 9 RS485/RS232 infrared Terminal block RS485 |
Time synchronisation protocol | GPS: Truetime/Datum IRIG-B |
Data recording | Harmonics logs Sag and swell logs Data logs Alarms Revenue logs Time stamping Event logs Historical logs GPS synchronisation |
Transmission Rate | 300...57600 bauds 57600 bauds 300...115200 bauds 10/100 Mbit/s <= 19200 bauds |
Memory capacity | 32 MB |
Web services | Alarm notification by e-mail Web server Robust security logs Port addressing user designed |
Ethernet service | SNMP-Traps and SYSLOG Enable/disable serial ports Enable/disable Ethernet protocols |
Tamperproof of settings | Protected by access code |
Compatibility code | ION8650C |
Environment | |
Electromagnetic compatibility | Electrostatic discharge immunity test conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 Conducted and radiated emissions B conforming to CISPR 22 Conducted RF disturbances conforming to IEC 61000-4-6 Immunity to impulse waves conforming to IEC 61000-4-12 |
Mounting Mode | Socket-mounted |
Mounting support | Enclosure door |
Type of Installation | Indoor installation |
Overvoltage category | III |
IP degree of protection | IP65 front face: IP51 back: |
Relative humidity | 5…95 % |
Pollution degree | 2 |
Ambient air temperature for operation | -40…185 °F (-40…85 °C) |
Ambient Air Temperature for Storage | -40…185 °F (-40…85 °C) |
Operating altitude | 0...9842.52 ft (0...3000 m) |
Standards | ANSI C12.1 IEC 62052-11 |
Width | 7.008 in (178 mm) |
Depth | 9.3 in (237 mm) |
Height | 7.008 in (178 mm) |
Net Weight | 15.4 lb(US) (7 kg) |
Ordering and shipping details | |
Category | US1PM1S09749 |
Discount Schedule | PM1S |
GTIN | 3606487732020 |
Returnability | No |
Country of origin | CA |
Packing Units | |
Unit Type of Package 1 | PCE |
Nbr. of units in pkg. | 1 |
Package 1 Height | 10.2 in (26.0 cm) |
Package 1 Width | 11.02 in (28.0 cm) |
Package 1 Length | 17.3 in (44.0 cm) |
Package weight(Lbs) | 9.9 lb(US) (4.5 kg) |
Compliance | |
Compliance | TAA BAA BABA BAA via COTS |
Contractual warranty | |
Warranty | 18 months |